BMS 16Ss

LiGen BMS - 16S

BMS 16Ss

LiGen BMS - 16S

LiGen BMS - 16S

Features

bms Title 16

Specifications

Ligen Power Inverters

Parameter

Description

Specification

Unit

Discharge

Continuous Discharge Current

10

20

30

40

50

60

Ampere (A)

Charging

Charging Voltage

58.4

Volt (V)

Recharging Current

10

20

30

40

50

60

Ampere (A)

Over-charge

Protection

Over-charge Detection Voltage

3.65 ±0.025

Volt (V)

Over-charge Protection Delay

1200

Milliseconds (ms)

Over-charge Release Voltage

3.45 ±0.05

Volt (V)

Balancing

Battery Balance Detection Voltage

3.6

Volt (V)

Battery Balance Release Voltage

3.6

Volt (V)

Battery Balance Current

74

Milliampere (mA)

Over-discharge Protection

Over-discharge Detection Voltage

2.5 ±0.05

Volt (V)

Over-discharge Protection Delay

140

Milliseconds (ms)

Over-discharge Release Voltage

3.0 ±0.05

Volt (V)

Over-current Protection

Over-current Detection Voltage

200

Millivolt (mV)

Over-current Protection Release Condition

Disconnect Load

NA

Short-circuit Protection

Short-circuit Protection Condition

Short-circuit of External Load

NA

Short-circuit Detection Delay

250

Microseconds (ms)

Short-circuit Protection Release Condition

Disconnect Load

NA

Self-consumption

Working Current

 20

Microampere (mA)

Sleeping Current

 10

Microampere (mA)

Operating Temperature

Temperature Range

-30 to 85

oC