LiGen BMS - 3S
LiGen BMS - 3S
LiGen BMS - 3S
Features
- Over-charge Protection
- Over-discharge Protection
- Over-current Protection
- Temperature Protection
- Short-circuit Protection
- Cell Balancing
- Highly Configurable
Specifications
Ligen Power Inverters
Parameter |
Description |
Specification |
Unit |
|||||||
Discharge |
Continuous Discharge Current |
10 |
20 |
30 |
40 |
50 |
60 |
80 |
100 |
Ampere (A) |
Charging |
Charging Voltage |
12.75 |
Volt (V) |
|||||||
Recharging Current |
10 |
20 |
30 |
40 |
50 |
60 |
80 |
100 |
Ampere (A) |
|
Over-charge Protection |
Over-charge Detection Voltage |
4.25 ±0.025 |
Volt (V) |
|||||||
Over-charge Protection Delay |
1200 |
Milliseconds (ms) |
||||||||
Over-charge Release Voltage |
4.1 ±0.05 |
Volt (V) |
||||||||
Balancing |
Battery Balance Detection Voltage |
4.15 |
Volt (V) |
|||||||
Battery Balance Release Voltage |
4.1 |
Volt (V) |
||||||||
Battery Balance Current |
74 |
Milliampere (mA) |
||||||||
Over-discharge Protection |
Over-discharge Detection Voltage |
2.5 ±0.05 |
Volt (V) |
|||||||
Over-discharge Protection Delay |
140 |
Milliseconds (ms) |
||||||||
Over-discharge Release Voltage |
3.0 ±0.05 |
Volt (V) |
||||||||
Over-current Protection |
Over-current Detection Delay |
8 |
Milliseconds (ms) |
|||||||
Over-current Protection Release Condition |
Disconnect Load |
NA |
||||||||
Short-circuit Protection |
Short-circuit Protection Condition |
Short-circuit of External Load |
NA |
|||||||
Short-circuit Detection Delay |
250 |
Microseconds (ms) |
||||||||
Short-circuit Protection Release Condition |
Disconnect Load |
NA |
||||||||
Self-consumption |
Working Current |
20 |
Microampere (mA) |
|||||||
Sleeping Current |
10 |
Microampere (mA) |
||||||||
Operating Temperature |
Temperature Range |
-30 to 85 |
oC |