LiGen BMS - 8S
LiGen BMS - 8S
LiGen BMS - 8S
Features
- Over-charge Protection
- Over-discharge Protection
- Over-current Protection
- Temperature Protection
- Short-circuit Protection
- Cell Balancing
- Highly Configurable
Specifications
Ligen Power Inverters
Parameter |
Description |
Specification |
Unit |
|||||
Discharge |
Continuous Discharge Current |
10 |
20 |
30 |
40 |
50 |
60 |
Ampere (A) |
Charging |
Charging Voltage |
29 |
Volt (V) |
|||||
Recharging Current |
10 |
20 |
30 |
40 |
50 |
60 |
Ampere (A) |
|
Over-charge Protection |
Over-charge Detection Voltage |
3.65 ±0.025 |
Volt (V) |
|||||
Over-charge Protection Delay |
1200 |
Milliseconds (ms) |
||||||
Over-charge Release Voltage |
3.45 ±0.05 |
Volt (V) |
||||||
Balancing |
Battery Balance Detection Voltage |
3.6 |
Volt (V) |
|||||
Battery Balance Release Voltage |
3.6 |
Volt (V) |
||||||
Battery Balance Current |
74 |
Milliampere (mA) |
||||||
Over-discharge Protection |
Over-discharge Detection Voltage |
2.5 ±0.05 |
Volt (V) |
|||||
Over-discharge Protection Delay |
140 |
Milliseconds (ms) |
||||||
Over-discharge Release Voltage |
3.0 ±0.05 |
Volt (V) |
||||||
Over-current Protection |
Over-current Detection Voltage |
200 |
Millivolt (mV) |
|||||
Over-current Protection Release Condition |
Disconnect Load |
NA |
||||||
Short-circuit Protection |
Short-circuit Protection Condition |
Short-circuit of External Load |
NA |
|||||
Short-circuit Detection Delay |
250 |
Microseconds (ms) |
||||||
Short-circuit Protection Release Condition |
Disconnect Load |
NA |
||||||
Self-consumption |
Working Current |
20 |
Microampere (mA) |
|||||
Sleeping Current |
10 |
Microampere (mA) |
||||||
Operating Temperature |
Temperature Range |
-30 to 85 |
oC |
Specifications
Ligen Power Inverters
Parameter | Description | Specification | Unit | |||||
Discharge | Continuous Discharge Current | 10 | 20 | 30 | 40 | 50 | 60 | Ampere (A) |
Charging | Charging Voltage | 34 | Volt (V) | |||||
Recharging Current | 10 | 20 | 30 | 40 | 50 | 60 | Ampere (A) | |
Over-charge Protection | Over-charge Detection Voltage | 4.25 0.025 | Volt (V) | |||||
Over-charge Protection Delay | 1200 | Milliseconds (ms) | ||||||
Over-charge Release Voltage | 4.1 0.05 | Volt (V) | ||||||
Balancing | Battery Balance Detection Voltage | 4.15 | Volt (V) | |||||
Battery Balance Release Voltage | 4.1 | Volt (V) | ||||||
Battery Balance Current | 74 | Milliampere (mA) | ||||||
Over-discharge Protection | Over-discharge Detection Voltage | 2.5 0.05 | Volt (V) | |||||
Over-discharge Protection Delay | 140 | Milliseconds (ms) | ||||||
Over-discharge Release Voltage | 3.0 0.05 | Volt (V) | ||||||
Over-current Protection | Over-current Detection Voltage | 200 | Millivolt (mV) | |||||
Over-current Protection Release Condition | Disconnect Load | NA | ||||||
Short-circuit Protection | Short-circuit Protection Condition | Short-circuit of External Load | NA | |||||
Short-circuit Detection Delay | 250 | Microseconds (ms) | ||||||
Short-circuit Protection Release Condition | Disconnect Load | NA | ||||||
Self-consumption | Working Current | 20 | Microampere (mA) | |||||
Sleeping Current | 10 | Microampere (mA) | ||||||
Operating Temperature | Temperature Range | -30 to 85 | oC |